LED SKINCARE
Formulating for light: what changes when skincare meets an LED device
Formulating for light: what changes when skincare meets an LED device
6 November 2026 · Fabrizio Todaro
Three questions to check when a serum or mask is used with a light device.

Key points
When a serum or mask is used with an LED device, the formula and the light behave as one system.
Three separate questions: does the light change the formula, does the formula change the light, and does the combination change the safety picture?
Fluorescence is a signal, not a conclusion, and neither fluorescence nor photostability alone demonstrates efficacy.
A claim about use with an LED session needs evidence relevant to the finished product and the claimed benefit.
Key points
When a serum or mask is used with an LED device, the formula and the light behave as one system.
Three separate questions: does the light change the formula, does the formula change the light, and does the combination change the safety picture?
Fluorescence is a signal, not a conclusion, and neither fluorescence nor photostability alone demonstrates efficacy.
A claim about use with an LED session needs evidence relevant to the finished product and the claimed benefit.
Recently I wrote on LinkedIn about shining blue light on mushroom extracts. At a biotech company developing light-based approaches for skin, part of my work was exposing plant and mushroom extracts to blue and green LED light and measuring their absorption and fluorescence emission. The most useful lesson was about formulation: when a product is used with a light source, the formula and the light behave as one system.
Recently I wrote on LinkedIn about shining blue light on mushroom extracts. At a biotech company developing light-based approaches for skin, part of my work was exposing plant and mushroom extracts to blue and green LED light and measuring their absorption and fluorescence emission. The most useful lesson was about formulation: when a product is used with a light source, the formula and the light behave as one system.
Whether the device is used in a clinic or at home, a serum or mask applied before or during a session changes what the formulator needs to check.
Whether the device is used in a clinic or at home, a serum or mask applied before or during a session changes what the formulator needs to check.
Three questions, not one
I find it useful to separate three questions:
I find it useful to separate three questions:
Does the light change the formula?
Does the formula change the light?
Does the combination change the safety picture?
Does the light change the formula?
Does the formula change the light?
Does the combination change the safety picture?
Each needs different tests, and answering one does not answer the others.
Each needs different tests, and answering one does not answer the others.
1. Does the light change the formula?
A starting point is to identify chromophores: compounds that absorb at the wavelengths the device emits. Examples include many chlorophyll derivatives, with absorption bands in the blue and red; carotenoids and curcuminoids that absorb in the blue or blue-green region; and riboflavin, which absorbs blue light and can act as a photosensitiser. The exact spectrum depends on the compound and its environment. Absorbing light does not mean a compound will degrade. But some component of the system must absorb for any photochemical change to happen, and a photosensitiser can damage neighbouring ingredients that do not absorb at all.
A starting point is to identify chromophores: compounds that absorb at the wavelengths the device emits. Examples include many chlorophyll derivatives, with absorption bands in the blue and red; carotenoids and curcuminoids that absorb in the blue or blue-green region; and riboflavin, which absorbs blue light and can act as a photosensitiser. The exact spectrum depends on the compound and its environment. Absorbing light does not mean a compound will degrade. But some component of the system must absorb for any photochemical change to happen, and a photosensitiser can damage neighbouring ingredients that do not absorb at all.
So fluorescence is a signal, not a conclusion. A compound may fluoresce and remain stable; another may not fluoresce at all and still react. A change in fluorescence during exposure is a reason to look further, not proof of photodegradation: concentration, temperature, quenching and the optics of the matrix can all change the signal. Neither fluorescence nor photostability alone demonstrates efficacy.
So fluorescence is a signal, not a conclusion. A compound may fluoresce and remain stable; another may not fluoresce at all and still react. A change in fluorescence during exposure is a reason to look further, not proof of photodegradation: concentration, temperature, quenching and the optics of the matrix can all change the signal. Neither fluorescence nor photostability alone demonstrates efficacy.
A generic light-stability test with a lamp of a different spectrum may not reflect the conditions of use. What I would test instead:
A generic light-stability test with a lamp of a different spectrum may not reflect the conditions of use. What I would test instead:
the device’s emission spectrum and irradiance at the working distance, ideally measured;
the radiant exposure of one realistic session (time-averaged irradiance × exposure time), plus a justified worst-case margin;
a film of defined thickness, close to the amount actually applied;
before and after exposure: colour, absorbance spectrum and the content of key actives or markers;
a dark control kept at the same temperature, because devices can warm the skin and the product, and heat alone can explain some changes.
the device’s emission spectrum and irradiance at the working distance, ideally measured;
the radiant exposure of one realistic session (time-averaged irradiance × exposure time), plus a justified worst-case margin;
a film of defined thickness, close to the amount actually applied;
before and after exposure: colour, absorbance spectrum and the content of key actives or markers;
a dark control kept at the same temperature, because devices can warm the skin and the product, and heat alone can explain some changes.
2. Does the formula change the light?
A product left on the skin during a session sits between the source and the skin, and through absorption and scattering it can reduce or redistribute the light that reaches it. How much depends on the ingredients, their concentration and the film thickness: a strongly coloured or opaque layer can matter more than a clear, thin one.
A product left on the skin during a session sits between the source and the skin, and through absorption and scattering it can reduce or redistribute the light that reaches it. How much depends on the ingredients, their concentration and the film thickness: a strongly coloured or opaque layer can matter more than a clear, thin one.
Measuring the spectral transmittance of a defined film at the device’s wavelengths provides a practical first estimate. For scattering samples, an appropriate integrating-sphere configuration can measure total transmittance, collecting both directly and diffusely transmitted light. This helps distinguish light redirected within the transmitted field from light that is not transmitted through the film. It remains an in vitro approximation: on skin, the film is uneven and changes as it spreads and dries.
Measuring the spectral transmittance of a defined film at the device’s wavelengths provides a practical first estimate. For scattering samples, an appropriate integrating-sphere configuration can measure total transmittance, collecting both directly and diffusely transmitted light. This helps distinguish light redirected within the transmitted field from light that is not transmitted through the film. It remains an in vitro approximation: on skin, the film is uneven and changes as it spreads and dries.
If a brand claims that a product “enhances” or “works with” an LED session, the Responsible Person must ensure that the claim is supported by adequate and verifiable evidence relevant to the product and the benefit claimed (Regulation (EU) No 655/2013). For a claimed benefit of the product–device combination, ingredient data alone do not automatically establish that benefit; testing the finished product under the intended device conditions may be needed.
If a brand claims that a product “enhances” or “works with” an LED session, the Responsible Person must ensure that the claim is supported by adequate and verifiable evidence relevant to the product and the benefit claimed (Regulation (EU) No 655/2013). For a claimed benefit of the product–device combination, ingredient data alone do not automatically establish that benefit; testing the finished product under the intended device conditions may be needed.
3. Does the combination change the safety picture?
In the EU, a cosmetic product must be safe for human health under normal or reasonably foreseeable conditions of use. If the product is intended for use with a light device, that use is part of those conditions. Photosafety is often discussed in terms of UV, but visible-light absorption can also be relevant. As a scientific reference, not a cosmetic testing requirement, ICH S10 considers absorption between 290 and 700 nm when assessing the potential for direct phototoxicity of pharmaceuticals. For the cosmetic–device combination, a useful starting question is whether ingredients or photoproducts absorb at the device’s wavelengths and could produce a harmful photochemical response under the intended exposure conditions.
In the EU, a cosmetic product must be safe for human health under normal or reasonably foreseeable conditions of use. If the product is intended for use with a light device, that use is part of those conditions. Photosafety is often discussed in terms of UV, but visible-light absorption can also be relevant. As a scientific reference, not a cosmetic testing requirement, ICH S10 considers absorption between 290 and 700 nm when assessing the potential for direct phototoxicity of pharmaceuticals. For the cosmetic–device combination, a useful starting question is whether ingredients or photoproducts absorb at the device’s wavelengths and could produce a harmful photochemical response under the intended exposure conditions.
Often the answer will be reassuring. The point is to ask deliberately: give the safety assessor the device’s spectrum plus absorption and photostability data, and document the reasoning, rather than assuming the light is irrelevant because it is “only LED”.
Often the answer will be reassuring. The point is to ask deliberately: give the safety assessor the device’s spectrum plus absorption and photostability data, and document the reasoning, rather than assuming the light is irrelevant because it is “only LED”.
What this means for botanical and mushroom extracts
Extracts with similar names may behave differently under light: species, plant or mushroom part, extraction method, solvent and extraction time can all change which chromophores are present, and at what level. A light-stability result does not transfer automatically from one extract to another, even from the same plant.
Extracts with similar names may behave differently under light: species, plant or mushroom part, extraction method, solvent and extraction time can all change which chromophores are present, and at what level. A light-stability result does not transfer automatically from one extract to another, even from the same plant.
For suppliers, an absorption spectrum of the extract, with concentration, solvent, path length and measurement conditions stated, can be useful starting documentation. For turbid samples, the contribution of scattering needs to be considered.
For suppliers, an absorption spectrum of the extract, with concentration, solvent, path length and measurement conditions stated, can be useful starting documentation. For turbid samples, the contribution of scattering needs to be considered.
A short checklist
Before calling a formula “LED-compatible”, I would want:
Before calling a formula “LED-compatible”, I would want:
the device’s wavelengths, irradiance and session dose;
ingredient absorbance at those wavelengths;
stability under that light, against a dark control;
transmittance of the applied film;
a safety assessment that considers the device;
evidence relevant to the finished product and the claimed benefit of its use with the device.
the device’s wavelengths, irradiance and session dose;
ingredient absorbance at those wavelengths;
stability under that light, against a dark control;
transmittance of the applied film;
a safety assessment that considers the device;
evidence relevant to the finished product and the claimed benefit of its use with the device.
What changes is the starting point: the formula and the light need to be assessed as a system.
What changes is the starting point: the formula and the light need to be assessed as a system.
Frequently asked questions
Can a skincare product be called “LED-compatible” on the basis of ingredient data?
Not on its own. You need the device’s wavelengths, irradiance and session dose, ingredient absorbance at those wavelengths, stability under that light against a dark control, the transmittance of the applied film, a safety assessment that considers the device, and evidence relevant to the finished product and the claimed benefit.
Can a skincare product be called “LED-compatible” on the basis of ingredient data?
Not on its own. You need the device’s wavelengths, irradiance and session dose, ingredient absorbance at those wavelengths, stability under that light against a dark control, the transmittance of the applied film, a safety assessment that considers the device, and evidence relevant to the finished product and the claimed benefit.
Does an ingredient that absorbs blue light always degrade?
No. Absorbing light does not mean a compound will degrade. But some component of the system must absorb for a photochemical change to happen, and a photosensitiser such as riboflavin can damage neighbouring ingredients that do not absorb at all.
Does an ingredient that absorbs blue light always degrade?
No. Absorbing light does not mean a compound will degrade. But some component of the system must absorb for a photochemical change to happen, and a photosensitiser such as riboflavin can damage neighbouring ingredients that do not absorb at all.
How should light stability be tested for a product used with an LED device?
Use the device’s emission spectrum and irradiance at the working distance, the radiant exposure of one realistic session plus a justified worst-case margin, and a film of defined thickness. Compare colour, absorbance spectrum and key actives before and after exposure, against a dark control kept at the same temperature.
How should light stability be tested for a product used with an LED device?
Use the device’s emission spectrum and irradiance at the working distance, the radiant exposure of one realistic session plus a justified worst-case margin, and a film of defined thickness. Compare colour, absorbance spectrum and key actives before and after exposure, against a dark control kept at the same temperature.
Can a serum reduce the light that reaches the skin?
Yes. Through absorption and scattering, a product film can reduce or redistribute the light, depending on its ingredients, their concentration and the film thickness. Spectral transmittance of a defined film, measured with an integrating sphere for scattering samples, gives a first in vitro estimate.
Can a serum reduce the light that reaches the skin?
Yes. Through absorption and scattering, a product film can reduce or redistribute the light, depending on its ingredients, their concentration and the film thickness. Spectral transmittance of a defined film, measured with an integrating sphere for scattering samples, gives a first in vitro estimate.
Is photosafety only about UV?
No. Visible-light absorption can also be relevant. In the EU, use with a light device is part of the reasonably foreseeable conditions of use, so the safety assessment should consider whether ingredients or photoproducts absorb at the device’s wavelengths.
Is photosafety only about UV?
No. Visible-light absorption can also be relevant. In the EU, use with a light device is part of the reasonably foreseeable conditions of use, so the safety assessment should consider whether ingredients or photoproducts absorb at the device’s wavelengths.
Sources
Regulation (EC) No 1223/2009, Article 3 — https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32009R1223
Regulation (EU) No 655/2013 — https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32013R0655
ICH S10, Photosafety Evaluation of Pharmaceuticals — https://database.ich.org/sites/default/files/S10_Guideline.pdf
Regulation (EC) No 1223/2009, Article 3 — https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32009R1223
Regulation (EU) No 655/2013 — https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32013R0655
ICH S10, Photosafety Evaluation of Pharmaceuticals — https://database.ich.org/sites/default/files/S10_Guideline.pdf
About the author
Fabrizio Todaro is a cosmetic formulator and Product Innovation Specialist focused on Asian botanicals and functional mushrooms for the EU market. He helps brands and contract manufacturers assess ingredient documentation, specifications and claims before formulation.
About the author
Fabrizio Todaro is a cosmetic formulator and Product Innovation Specialist focused on Asian botanicals and functional mushrooms for the EU market. He helps brands and contract manufacturers assess ingredient documentation, specifications and claims before formulation.
Also published on LinkedIn.
Also published on LinkedIn.